Maine- (207)793-3940 · Upstate New York- (518)692-7218

The Hydrostatic Test equipment used is from Honeywell / Total Fire Inc.

Each item (Coat/Pants) is tested, in accordance with NFPA1851,

on at least 6 areas. These are areas of normal wear and stress on the

barrier, such as shoulders, underarm, and crotch.

If any one (1) area fails, the vapor barrier for that item is considered to have "FAILED" and is in need of repair or replacement.

A list of facilities that may be able to repair or replace the vapor barrier is available.

The Technician will set up the barrier for testing after the visual exam. If the item does not have a port to facilitate the test, one will be opened and re-sewn after testing.

The item is fed onto the arm of the tester.

Locked in place and one (1) psi is applied to the test area.

NO leakage is allowed for a "Passed" status.

The 1psi is held on the test area for 20 seconds.

Documentation of the "PASS/FAIL" will be recorded on the inspection paperwork generated during the visit.